Description
Operation
1. Put the unit on the workbench and put the handle on the holder. Connect well the power supply.
2. Install the nozzle on the handle. Select bigger caliber nozzle that fits with the IC.
3. Turn on the power switch. At the time, if the handle is on the holder, the unit will be in the
sleeping state.
Analog Type:
(1) On the waiting (sleeping) state, the heating light is not bright.
(2) Setting the temperature by circumvolving the temperature-controlling knob.
(3) Take up the handle on the holder, and then the unit begins work and the heating light is
bright.
(4) Adjusting the airflow by circumvolving the airflow-controlling knob.
(5) After finishing the work, take down the handle on the holder. After that, the unit cuts off the current to the heater and then the unit begins to blow cooling airflow. When the temperature is less than 100℃, the unit comes into the sleeping state.
Assemble and disassemble nozzle
1. Select the nozzle that matches the size of the IC. Attach the nozzle when both the steel pipe and the nozzle are cool.
2. Loosen the screw on the nozzle.
3. Attach the suited nozzle as shown in the drawing.
4. Fasten the screw properly and attach the nozzle on the pipe safely.
Reviews